Showing all 122 results

  • 2-16 Loops Addressable Fire Alarm Control Panel AS-9108E

    ANSORL 9108E fire alarm control panel is a new generation of fire alarm control panel.
    It can support uses of other related products of the Company to form an integrated alarm and linkage control system, which is perfectly suitable for the application of small and medium-sized fire alarm and firefighting and linkage integrated control system.
    The fire alarm control system is widely used in small and medium-sized firefighting engineering, such as high-grade office building, residence community, department store, gymnasium, exhibition room, library, workshop, supermarket and hotels.

    Product Features:

    1. Adopts the latest generation of high-speed microprocessor. Data processing rate and data storage capacity reach 100-fold and 1000-fold increase, respectively, compared to traditional technologies.
    2. ANSORL 9108E is provided with 7″ color display screen (LCD), with a display resolution
    of 800×480.
    3. The operation interface imitates Windows menus and window interfaces and is almost the same as the computer operating and using habits, thus facilitates the learning.
    4. Operation and control are flexible and convenient through the standard USB-interfaced
    computer keyboard and mouse. the panel buttons are used as field programming devices.
    5. T9 pinyin input method is provided and texts can be input easily and freely.
    6. Use smart U disk (optional), which can be used to copy or restore setup file and historical file of the system, thus facilitating the system maintenance.
    7. It adopts the non-polarity two-bus intelligent alarm linkage pattern and can connect 324
    intelligent detectors or intelligent modules at most. The addresses of module detectors can
    be mix-programmed (optional 1-324).
    8. Several high-speed CAN bus interface guarantee speedy and reliable data transmission.
    9. It can supports interconnection of 20 ANSORL9108E control units with CAN Bus and the
    maximum system capacity after networking reaches 16×324=5184 (alarm point). It can
    supports interconnection of 254 control units with Ethernet and the maximum system
    capacity after networking reaches 254×5184=1316731 (alarm point).
    10. The system has the function of recording operation history: 1000 pieces of historical fire alarms, historical requests, historical feedbacks, historical faults and historical operations,respectively.
    11. The user may customize the equipment type, which can facilitate the system linkage.
    12. It has the modular manual single-point start/stop functions, which can facilitate field
    debugging and testing.
    13. It has the single-point detector/module testing function, the detector working status and test data are clearly displayed.
    14. The system is provided with a dedicated mini-printer as standard, which is used to print various operating statuses of the system immediately.
    15. It can be accessed with area indicating panels, building indicating panels and floor indicating panels, which will extend display information of the control unit to corridor and other locations.
    16. It can be connected with PC contributing to display information of fire alarms (alternative).
    17. The system carries out the hierarchy management of multi-level users and the users of
    different levels are granted with corresponding operating system permissions, which is
    convenient for system management.
    18. It is possible to update the system on field or remotely to ensure the system operates stably and reliably.

     

  • AGD109 Addressable Combustible Gas Detector

    Product Features:

    AS-AGD109 Point type Combustible gas detector, which measurement range is 0~100% LEL, is with a new type thick film metal oxide semiconductor, screen printed gas sensor, for combustible gas detection, compatible with interconnected 9100E and MN3010 fire detection control panel, suitable for a wide range of small and medium sized projects like family, hotel, apartments, factories, etc.

  • AHD105 Addressable Heat Detector

    Product Features:

    • 1.Built-in standalone CPU, quick calculating speed and excellent stability.
    • 2.Non-polarity two-wire bus to make cabling easy, and avoid wrong wirin.
    • 3.Sealed robber type of heat sensitivity component enhances anti-humidity and anti-erosion.
    • 4.Three sensitivity levels of the detector are optional at the control panel to suit different environments.
    • 5.Temperature rising compensation to improve responsive capacity upon different temperature rising status.
    • 6.Special production process to make the device work at high temperature,high humidity and high altitude environment.
    • 7.ESD static protection grade 12000V, strong anti-interference ability.
  • AHS Addressable Strobe Sounder

    Product Features:

    • 1.Built-in standalone CPU, quick calculating speed and excellent stability
    • 2.Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring
    • 3.Sounder/ visual indicator setting freely according to different environment.
    • 4.With super bright red LED, it features markedness, long lifespan, and low consumption.
    • 5.Special production process to make the device work at high temperature, high humidity and high altitude environment6.ESD static protection grade 12000V, strong anti-interference ability.
  • AIM Input Module

    Product Features:

    1. Mode of operation: Nonpolar two-wire system
    2. Quiescent current: <0.5mA (bus); <6mA (power line)
    3. Action current: <2mA (bus); <15mA (power line)
    4. Operation indicator: The inspection indicator will blink once about every 12 seconds in the inspection status
    or remain lit in the operation status.
    5. Operating environment: Temperature: -10℃~50℃; relative humidity: ≤95% (40℃±2℃, without
    condensation)
    6. Terminal load: 4.7K resistance
    7. External dimensions: 86×86×40(mm)
    8. Weight: about 119g
    9. Executive standard: EN54-18

  • AIO Input/Output Module

    Product Features:

    1. Mode of operation: Nonpolar two-wire system
    2. Quiescent current: <0.6mA (power-down mode)
    3. Action current: <10mA
    4. Capacity of the output control contact: 2A@DC30V
    5. Operation indicator: The inspection indicator will blink once about every 12 seconds in the inspection status or remain lit in the output status; the input indicator will remain lit in the feedback status.
    6. Operating environment: Temperature: - 10℃ ~ 50 ; relative humidity: ≤95% ( ℃ 40 ±2 ℃ ℃, without condensation)
    7. Terminal load: 47K resistance
    8. External dimensions: 86×86×40(mm)
    9. Weight: about 130g
    10. Executive standard: EN54-18

  • AIS Isolator Module

    Product Features:

    1. Mode of operation: Nonpolartwo-wire system
    2. Quiescent current: <5.0mA
    3. Operative current: >200mA
    4. Operation indicator: Red (It is out in the normal monitoring status or remains lit in
    the operation status)
    5. Operating environment: Temperature: -10℃~50℃; relative humidity: ≤95%
    (40℃±2℃, without condensation)
    6. External dimensions: 86×86×40mm(with the base)
    7. Weight: about 125g (with the base)

  • AMCP Addressable Manual Call Point

    Product Features:

    • 1.Built-in standalone CPU, quick calculating speed and excellent stability.
    • 2.Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring.
    • 3.Pressing the lever sheet on the fire call points to confirm the fire alarm, it can be reset by the special tool.
    • 4.It has a built-in fire telephone jack and a PHONE indicator.
    • 5.Special production process to make the device work at high temperature, high humidity and high altitude environment.
    • 6.ESD static protection grade 12000V, strong anti-interference ability.
    • 7.It provides passive output contacts that can control other external equipment directly through an intermediate relay.
  • ART Addressable Repeater Panel

    Product Features:

    1.Built-in standalone CPU, quick calculating speed
    2.Connect the addressable panel by RS-485 bus, and each control panel can be with 99 units of fire display panels and KR-485 expansion cases, and each KR-485 expansion case can be with up to 50 fire display panel.
    3.It can give sound and light alarm signal, and support fault detecting and then warning by itself.
    4.Support set display area of fire repeater by control panel
    5.Special production process, the device can work at high temperature, high humidity, extremely cold, and high altitude environment.
    6.ESD static protection level 12000V, and strong anti-interference ability.
    7.It can display -9~89 floor fire information, and each fire repeater can display 99 pieces of fire alarm information or other feedback information.

  • AS-WHD105 Wireless Heat Detector

    AS-WHD105 wireless heat detector is an intelligent household fire detector with high-precision thermistor as the sensor, which can be used together with the wireless fire alarm control panel

    The detector uses advanced wireless transceiver technology and high-integration micro-processing chip to process data.

    Model No.
    AS-WHD105 
    Type
    ROR and FT
    Battery
    CR17450 3V
    Monitoring Current
    ≤10uA
    Alarm Current
    ≤18mA
    Coding Method
    Automatically assigned when networking
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
  • AS-WIO Wireless Input and Output Module

    AS-WIO Wireless Input and Output Module is suitable for installation in public places, factories and other environments.

    When there is a fire alarm, the module can not only send an alarm signal to the control panel through wireless communication technology after receiving the closing signal, but also output the closing signal for connection with other equipment.

    <

    Model No.
    AS-WIO
    Battery
    CR17450 3V
    Monitoring Current
    ≤14uA
    Alarm Current
    ≤18mA
    Led Indicators
    Output/input/fault/run
    Coding Method
    Automatically assigned when networking
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
  • AS-WMCP Wireless Manual Call Point

    AS-WMCP wireless manual call point is suitable for installation in public places, factories and
    other environments.

    When a fire is manually confirmed, press the button, and the red light of the MCP is always on, so that an alarm signal can be sent to the control panel through wireless communication technology.

    When the control panel responds to the alarm signal, the MCP enters a state of waiting for the control panel to reset, and the control panel displays the coded information of the MCP and gives an alarm sound.

    Model No.
    AS-WMCP
    Type
    Resettable
    Battery
    CR17450 3V
    Monitoring Current
    ≤10uA
    Alarm Current
    ≤18mA
    Coding Method
    Automatically assigned when networking
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
  • AS-WRT Wireless Signal Transmitter

    AS-WRT Wireless signal transmitter is suitable for home wireless alarm system and industrial wireless alarm system.

    The transmitter uses advanced wireless transceiver technology, built-in efficient anti-collision algorithm, and can set filtering rules, so that the transmitter can work reliably in the system.

    The transmitter supports multiple groups of channels, so that the transmitter can work in complex environments and in the presence of multiple hosts, realizing mutual non-interference, truly avoiding the collision of channels, and greatly improving the coverage of wireless networks.

    Model No.
    AS-WRT
    Main Power
    DC5V (Power Adapter)
    Standby Power
    3V/2400MAh
    Operation Indicator
    Flash when normal
    Fault Indicator
    On when standby power fails
    Communication Indicator
    Flash when forwarding info
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
  • AS-WSD102 Wireless Photoelectric Smoke Detector

    AS-WSD102 wireless photoelectric smoke detector is an intelligent fire detector based on the principle of transmitting and receiving high-precision infrared tubes, which can be used with our wireless fire alarm control panel.

    The detector uses 470MHz wireless transceiver technology to process data with a highly
    integrated micro-processing chip.
    It has the characteristics of high sensitivity, long transmission distance and low power consumption.

    Model No.
    AS-WSD102
    Type
    Photoelectric
    Battery
    CR17450 3V
    Monitoring Current
    ≤10uA
    Alarm Current
    ≤18mA
    Coding Method
    Automatically assigned when networking
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%

  • AS-WSG Wireless Strobe Sounder

    AS-WSG wireless sounder strobe is suitable for installation in public places, factories and other
    environments, and is used together with our wireless fire alarm control panel.

    When the control panel receives the fire alarm instructions from other fire alarm devices, the control panel starts the alarm through wireless signals, and the alarm sends out sound and light signals to achieve the purpose of audible and visual alarm.

    Model No.
    AS-WSG
    Battery
    CR17450 3V
    Monitoring Current
    ≤45uA
    Alarm Current
    ≤240mA
    Sound Level
    75~115dB
    Coding Method
    Automatically assigned when networking
    Radio Frequency
    Transmit power <20dBm
    Frequency Band
    470MHz
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
  • ASD102 Addressable Smoke Detector

    Product Features:

    • 1.Built-in standalone CPU, quick calculating speed and excellent stability.
    • 2.Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring
    • 3.Built-in a standalone CPU which can process the sampling data in real-time.
    • 4.It adopts backward scattering maze and makes it more sensitive to detect the smoke generated from burning of different materials.
    • 5.Support sensor fault inspecting and reporting to ensure system work and maintain well
    • 6.Three sensitivity levels of the detector are optional at the control panel to suit different environments.
    • 7.Drift compensation to reduce nuisance alarms.
    • 8.Special production process to make the device work at high temperature, high humidity and high altitude environment
    • 9.ESD static protection grade 12000V, strong anti-interference ability
  • ASH107 Addressable Smoke/Heat Combined Detector

    Product Features:

    • 1.Composite smoke-sensing and temperature-sensing detector is a multi-element composite detector constituted jointly by a smoke sensor and a semiconductor temperature sensor in respect of technological structure and circuit structure.
    • 2.Built-in standalone CPU, quick calculating speed and excellent stability.
    • 3.Non-polarity two-wire bus to make cabling easy, and avoid wrong wiring.
    • 4.It adopts backward scattering maze and makes it more sensitive to detect the smoke generated from burning of different materials.
    • 5.Sealed robber type of heat sensitivity component enhances anti-humidity and anti-erosion.
    • 6.Three sensitivity levels of the detector are optional at the control panel to suit different environments.
    • 7.Drift compensation to reduce nuisance alarms.
    • 8.Temperature rising compensation to improve responsive capacity upon different temperature rising status.
    • 9.Support sensor fault inspecting and reporting to ensure system work and maintain well.
    • 10.Special production process to make the device work at high temperature, high humidity and high altitude environment.
    • 11.ESD static protection grade 12000V, strong anti-interference ability.
  • Automatic Air Vent

    Automatic Air Vent
    Automatic Air Vent is a kind of controller is installed on the system architecture.Automatic Air Vent is a kind of controller is installed on the system architecture, used to release the heat supply system and water supply pipeline of air-pocket valve, widely used in manifold, radiator, floor heating, air conditioning and water system.

    product features :
    1. Automatic exhaust valve must be installed vertically, namely must ensure that its internal buoy is in vertical position, so as not to affect the exhaust;
    2. Automatic exhaust valve in the installation, it is best with isolation valve installation, so when you need to tear open the discharge valve for maintenance, the guarantee system of airtight, water does not drain;
    3. Automatic exhaust valve is installed in the highest point of the system, is helpful to improve the efficiency of exhaust.

  • AW-BIN2-100 2 Ways Breeching Inlet Fire Hydrant Landing Valve

    AW-BIN2-100 2 Ways Breeching Inlet Fire Hydrant Landing Valve
    Join fire water mains and water feeder fire-fighting equipment.
    Product features :

     2 Ways Breeching Inlet Manifold in a water system, used to connect various heating tube of supply and return water, water collection device.

  • AW-BLV65 Brass Sand Casting Oblique Type Landing Valve

    AW-BLV65 Brass Sand Casting Oblique Type Landing Valve
    Fire Hydrant Landing Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.
    Product features :

    It is usually placed inside of fire cabinet and used cooperatively with fire hose reel and fire nozzle. According to fix structure, it is divided to female and male.

  • AW-BLV65-F Brass Sand Casting Oblique Type Fire Hydrant Landing Valve With Flange

    AW-BLV65-F Brass Sand Casting Oblique Type Fire Hydrant Landing Valve With Flange
    Fire Hydrant Landing Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.
    Product features :

    It is usually placed inside of fire cabinet and used cooperatively with fire hose reel and fire nozzle. According to fix structure, it is divided to female and male.

  • AW-EXMJH Explosion Proof Module

    AW-EXMJH Explosion Proof Module

    AW-EXMJH explosion proof module (wiring) box is performance in line with GB3836-2000 series of standards, and inspected by the state designated inspection units, made explosion proof certificate.AW-EXMJH explosion proof module (wiring) box is performance in line with GB3836-2000 series of standards, and inspected by the state designated inspection units, made explosion-proof certificate. DFMJX-proof module (junction) box suitable for Zone 1, Zone 2 contains Ⅱ class A, B, C hazardous location temperature class T1 ~ T6 group explosive gas environment.

    AW-EXMJH explosion-proof module (wiring) box is a indispensable equipment in explosion-proof fire alarm system which can be installed inside any of the company’s various modules, you can also install a variety of terminal blocks, field wiring as sub-line equipment.

    Product features :

    AW-EXMJH explosion proof module (wiring) box housing is made of cast aluminum alloy. Electrostatic spraying outer surface has a good protective properties.

    ​AW-DFMKX explosion proof module (wiring) box interior size, presence of aperture size and appear caliber number can be designed by user requirements.

  • AW-EXYS Explosion-Proof Speaker

    AW-EXYS Explosion-Proof Speaker
    AW-EXYS explosion-proof speakers (hereinafter speakers) is constant pressure bass speaker (can be customized to provide constant resistance type), which explosion-proof performance in line with GB3836… AW-EXYS explosion-proof speakers (hereinafter speakers) is constant pressure bass speaker (can be customized to provide constant resistance type), which explosion-proof performance in line with GB3836-2000 series of standards, inspected by the state designated inspection units, and acquired explosion-proof certificate. Speakers is available in 1 and 2 Zone hazardous locations which include Class Ⅱ A, B, C class T1 ~ T6 temperature group explosive gas environment.
    Product features :
    AW-EXYS explosion-proof speakers for flammable and explosive places such as petroleum, chemical, textile, military, electric power, metallurgy, pharmaceutical and other industries, used as terminal equipment for production scheduling, communication and fire radio.

    AW-EXYS explosion-proof speakers is a currently leading explosion-proof communication product, because of it’s reliable performance and good security performance.

    AW-EXYS explosion-proof speakers installation is divided into wall-mounted and ceiling mounted.
    Wall-mounted: the explosion-proof speaker can be shackled with fixed beams with 2-M8 screws on the wall.
    Ceiling mounted installation is divided into the suspended ceiling (surface mounted) and the ceiling (panel mounted). Suspended ceiling installation is for the workshop plant installation. Through lengthening the lifting beam length can vary the height of the speaker from the floor; Ceiling is suitable for office and other indoor places. Speaker body embedded within the ceiling opening hole circle to make shed clean and beautiful.

  • AW-EXYS-15 Explosion Proof Speaker

    Speaker Explosion Proof AW-EXYS-15

    Speaker tahan ledakan (explosion proof) AW-EXYS-15 adalah speaker pengeras suara model tanduk dengan treble bertekanan konstan (dapat disesuaikan untuk memberikan tipe resistansi konstan), yang kinerja tahan ledakannya sesuai dengan seri standar GB3836-2000, yang telah teruji dan memperoleh sertifikat uji anti ledakan (explosion proof). Perangkat ini dibuat khusus untuk digunakan zona di 1 dan 2, klasifikasi zona lokasi berbahaya dengan kandungan gas eksplosif pada kelompok suhu Kelas Ⅱ A, B, C kelas T1 ~ T6.

    Fitur produk:

    Speaker explosion proof AW-EXYS-15 ditempatkan di area yang mudah terbakar dan meledak seperti minyak bumi, kimia, tekstil, militer, tenaga listrik, metalurgi, farmasi, dan industri lainnya. Proses transmisi speaker menggunakan elemen jaring logam tahan ledakan stainless steel paling canggih yang memiliki redaman suara, kapasitas distribusi, kekuatan mekanik yang tinggi, dan fitur keselamatan ledakan.

    Speaker tahan ledakan AW-EXYS-15 adalah produk komunikasi tahan ledakan terpopuler saat ini, karena kinerjanya yang andal dan kinerja keamanan yang baik.

  • AW-IFH-65-A Single Outlet Landing Valve Fire Hydrant

    AW-IFH-65-A Single Outlet Landing Valve Fire Hydrant

    Indoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.
    Product features :

    It is usually placed inside of fire cabinet and used cooperatively with fire hose reel and fire nozzle. According to fix structure, it is divided to female and male.

  • AW-IFH-65-SD Dual Outlet Landing Valve Fire Hydrant

    AW-IFH-65-SD Dual Outlet Landing Valve Fire Hydrant
    Indoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

    Product features :
    It is usually placed inside of fire cabinet and used cooperatively with fire hose reel and fire nozzle. According to fix structure, it is divided to female and male.

  • AW-IFH-65B Single Outlet Landing Valve Fire Hydrant

    AW-IFH-65B Single Outlet Landing Valve Fire Hydrant
    Indoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

    Product features :
    It is usually placed inside of fire cabinet and used cooperatively with fire hose reel and fire nozzle. According to fix structure, it is divided to female and male.
  • AW-LFH100 Outdoor Landing Fire Hydrant

    AW-LFH100 Outdoor Landing Fire Hydrant
    Outdoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. Outdoor fire hydrant is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.
    Product features :

    Outdoor fire hydrant is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.

  • AW-PFH100 2 Way Pillar Fire Hydrant

    AW-PFH100 2 Way Pillar Fire Hydrant
    2 Way Pillar Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place.

    Product features:

    2 Way Pillar Fire Hydrant  is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.

  • AW-PFV65 Pressure Regulating Fire Hydrant Valve

    AW-PFV65 Pressure Regulating Fire Hydrant Valve
    Pressure Regulating Fire Hydrant Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

    Product feature :
    Pressure Regulating Fire Hydrant Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place.

    It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

  • AW-PFV65-F Pressure Regulating Fire Hydrant Valve With Flange

    AW-PFV65-F Pressure Regulating Fire Hydrant Valve With Flange
    Pressure Regulating Fire Hydrant Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place. It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

    Product features :
    Pressure Regulating Fire Hydrant Valve is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place.

    It is a fixed fire hydrant used for putting out fire in buildings such as factory, warehouse, high buildings even as well as ships.

  • AW-UFH100-10065 Underground Fire Hydrant

    AW-UFH100-10065 Underground Fire Hydrant
    Outdoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place.
    Product features:

    Outdoor fire hydrant is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.

  • AW-UFH100-65S Single Outlet Underground Fire Hydrant

    AW-UFH100-65S Single Outlet Underground Fire Hydrant
    Outdoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place
    Product features:
    Outdoor fire hydrant is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.
  • AW-UHR100-65D Dual Outlet Underground Fire Hydrant

    AW-UHR100-65D Dual Outlet Underground Fire Hydrant
    Outdoor Fire Hydrant is a valve Interface that placed on fire protection pipe nets in buildings and supply water to fire place.
    Product features:

    Outdoor fire hydrant is used for supplying fire water and necessary fire protection facility of town, street, industrial and mining enterprise, ware house government buildings, schools and hospitals etc.

  • Ball Valve(Brass Material)

    Ball Valve(Brass Material)
    The confluence of ball valve can be flexible control medium, shunt, and the flow switch, at the same time also can close any channel and make the other two.
    Product features : 
    1. The fluid resistance is small, little flow resistance full size of ball valve.
    2. Simple structure, small volume, light weight.
    3. Compact and reliable.
    4. Easy to operate, open and close quickly.
    5. Easy maintenance, simple structure of ball valve, sealing ring, which generally remove replacement is more convenient.
    6. In the fully open or fully closed, the ball and seat sealing surface and the dielectric isolation, medium through, can not cause the valve sealing surface erosion.
    7. Wide application scope.
  • Ball Valve(Cast Iron Material)

    Ball Valve(Cast Iron Material)
    The confluence of ball valve can be flexible control medium, shunt, and the flow switch, at the same time also can close any channel and make the other two.
    Product features :
    1. The fluid resistance is small, little flow resistance full size of ball valve.
    2. Simple structure, small volume, light weight.
    3. Compact and reliable.
    4. Easy to operate, open and close quickly.
    5. Easy maintenance, simple structure of ball valve, sealing ring, which generally remove replacement is more convenient.
    6. In the fully open or fully closed, the ball and seat sealing surface and the dielectric isolation, medium through, can not cause the valve sealing surface erosion.
    7. Wide application scope.
  • BD103EX Explosion Proof Beam Smoke Detector

    Detektor asap sinar inframerah explosion proof AS-BD103EX terdiri dari alat pemancar dan penerima sensor inframerah. Alat ini dipasang saling berhadapan di ujung dinding yang berlawanan, untuk menciptakan area yang terlindungi. Alat ini memberikan sinyal alarm setelah konsentrasi asap mencapai volume tertentu. Produk ini sangat cocok untuk area ruang yang luas, bangunan dengan langit-langit tinggi seperti gudang, pabrik, bandara, lobi hotel, pusat perbelanjaan, dll.

    Type
    Explosion Proof
    Operating Voltage
    24VDC
    Standby Current
    ≤10mA
    Alarm Current
    ≤25mA
    Explosion Proof Mark
    Exd (ib) II CT6
    Detection Distance
    3-100m
    Detector Protective Diameter
    14m
    The Ambient Temperature
    -10 ° C ~ +55 ° C
    Relative Humidity
    ≤95% (non-condensing)
  • Bell-6 Fire Bell

    The AS-BELL-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.

    The system designer must make sure that the total current drawn by the devices on the loop does not exceed the current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage.

    When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from electrical handbooks.

    Product Features:

    Range: DC24V
    Alarm Current Maximum 70 mA @ 24 VDC
    Alarm Sound Intensity: Minimum 95dB
    Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
    Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
    Input terminal Wire Gauge: 12 to 18 AWG
    Dimensions: Diameter 150mm, Height 45mm
    Weight: Net Weight 670g, Gross Weight 720g

  • BELL-EX Explosion Proof Alarm Bell

    Fire alarm explosion proof AS-BELL-EX adalah perangkat tipe konvensional dengan output relay, kompatibel dengan sebagian besar panel kontrol fire alarm di pasaran.

    Fire alarm explosion proof AS-BELL-EX adalah perangkat penting dalam sistem alarm kebakaran. Ketika terjadi kebakaran, panel kontrol menerima sinyal alarm dari detector kebakaran atau titik manual call point, kemudian panel mengirimkan sinyal start ke bel, yang akan membuat alarm berbunyi.

    Fire alarm explosion proof AS-BELL-EX mematuhi standar GB3836-2010 untuk kinerja tahan ledakan. Fire alarm explosion proof ini dapat digunakan di Zona 1 dan zona 2, mencakup area berbahaya dengan atmosfer gas eksplosif kelas II B dan II C dengan suhu T6.

    Type
    Explosion Proof
    Power Supply 1
    24VDC (standard)
    Power Supply 2
    AC220V (customized)
    Alarm Current
    ≤35mA
    Sound Intensity
    ≤100dB
    Material
    Cast aluminum alloy
    Explosion Proof mark
    Exd II CT6
    The Ambient Temperature
    -20° C ~ +50° C
    Relative Humidity
    ≤95% (non-condensing)
  • BFP-16 Fire Alarm Control Panel

    The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users.

    The panel can be wall mounted and the generously sized metal back box allows ample space for rear or top cable entries.

    A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors.

    Each of the system components has been specifically designed to operate as part of the system.  This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.

    This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.

     

    Model No.
    AS-BFP Series
    Main Power Supply
    90 to 270VAC, 50Hz
    Ambient Temperature
    Operating -10℃~+55℃
    Ambient Humidity
    ≤95% , no condensation
    Power Supply Rating
    3 Amps @ 24VDC
    Backup Battery
    2 pcs lead acid battery
    Initiating Device Circuits
    4 – 16 detection zones
    Notification Appliance Circuits
    1 – 4 sounder lines
    Maximum Detector Per Zone
    25 – 30 detectors
    Relay Contact Rating
    2A & 30VAC, resistive
    Standard
    EN54-2 & EN54-4
  • BHD102 Stand-Alone Heat Detector

    This heat sensor is designed for detect heat,it adopt SMT Manufacturing Process and contains  highSensitive sensor,when the temperature reached +65 degree,it will give off alarm.

    After installation, the detector will be in working status when electrified. On working status, the indicator LED will flash about once per minute.
    When the detector sense the temperature is higher than the preset temperature, it will ring loudly pulse alarm sound. And the red indicator LED will flash rapidly. It will not stop till the circumstance temperature is lower than the preset temperature.

    Parameter:

    Power: 9V DC
    Working Current: Static State Current<10uA
    Working Current Ranges:20-50mA
    Alarm Temperature: Standard 65℃
    Buzzer Sound Level: 85dB Distance 10 inches

  • DZ102S Addressable Strobe Sounder Base

    The strobe sounder is designed with an upper cover and a lower
    cover and installed on an independent base, it can be installed,
    debugged and maintained conveniently.
    It can realize electronic coding and rewrite the address via coder in situ.
    It uses multiple super bright red LEDs as light sources for visual display, ensuring a striking display, a longer service life and low power consumption.
    It is designed as fire detector base and strobe sounder together, can be connected with the fire detector model AS-ASD102,
    AS-AHD105, AS-ASH107. The detector can be fixed by installing
    above the strobe sounder base, thus realizing the linkage of the
    alarm system.
    Matched host machine: AS-MN3010, AS-9108E.

    Parameters

    Operating voltage: DC24V ± 20%
    Quiescent current: ≤1mA; Alarm current: ≤130mA@DC24V
    Operating temperature: -10℃~+55℃;
    Relative humidity: ≤95% (40℃, without condensation)
    Flushing rate: 1Hz~2Hz ;
    Alarm volume: 75dB~120dB
    Variable cycle: 4s-4.5s

  • E302-IR3 Explosion-Proof IR3 Flame Detector

    ☆ Detektor api AS-E302-IR3 menyediakan kemampuan deteksi kebakaran generasi baru dan standar teknis.

    ☆ Detektor api AS-E302-IR3 mengadopsi sensor piroelektrik inframerah dengan sistem arus sempit yang baru, memampukan membedakan radiasi nyata dari api dan sumber interferensi dengan lebih efektif.

    ☆ Detektor api AS-E302-IR3 dilengkapi dengan prosesor mikro 32-bit dan algoritma pemrosesan sinyal lebih akurat, dapat mendeteksi sinyal api dengan cepat, mengurangi jeda waktu respons, meningkatkan akurasi deteksi, dan mengurangi tingkat alarm palsu.

    ☆ Detektor api AS-E302-IR3 menjaga performa tahan ledakan, perlindungan, dan ketahanan terhadap korosi.

    ☆ Detektor api AS-E302-IR3 berukuran lebih kecil, lebih ringan, dan lebih mudah dipasang dibandingkan dengan detektor versi sebelumnya.

    ☆ Perangkat terintegrasi dengan processing chip data 32-bit berkecepatan tinggi, rendah daya, kinerja tinggi, dan presisi tinggi.

    ☆ Mengadopsi sensor piroelektrik inframerah arus sempit yang baru.

    ☆ Api kecil dapat dideteksi lebih awal.

    ☆ Jarak deteksi adalah 40 meter (api dengan n-heptana ukuran 0,33m, 0,33m, 0,05m).

    ☆ Algoritma yang sempurna menggabungkan optimal deteksi api dan kemampuan alarm palsu.

    ☆ Detektor cocok untuk berbagai jenis bahan bakar.

    ☆ Cocok untuk aplikasi industri berat.

    ☆ Desain tahan ledakan dapat digunakan di area berbahaya di lokasi industri.

    ☆ Biaya pemeliharaan rendah, mudah diperbarui dan ditingkatkan.

  • E302-UV Explosion-Proof UV Flame Detector

    • ☆ AS-E302-UV flame detector provide a new generation of fire detection capability and technical standards.
    • ☆ AS-E302-UV flame detector adopts a specially designed “Daylight-blind” UV photoelectric sensor, which is imported from Japan, the sensor spectral range is 185~260nm. It can effectively distinguish the real flame radiation and interference sources.
    • ☆ AS-E302-UV flame detector is built-in a 32-bit microprocessor and patented signal processing algorithm, it can detect flame signals quickly, reduce response time, increase detection accuracy, reduce false alarm rate.
    • ☆ AS-E302-UV flame detector maintains the performance of explosion-proof, protection, corrosion resistance.
    • ☆ AS-E302-UV flame detector is smaller, lighter, more convenient to install comparing to our old version detector.
    • ☆ Built-in 32-bit high-speed, low-power, high-performance, high-precision data processing chip.
    • ☆ Adopt patented and fast response UV optical sensor.
    • ☆ A small fire can be detected earlier.
    • ☆ The detection distance is 35 meters (0.33m*0.33m*0.05m n-heptane fire).
    • ☆ The perfect algorithm combines optimally the flame detection and false alarm capabilities.
    • ☆ Detector is fit to a variety of fuels.
    • ☆ Apply to heavy industry applications.
    • ☆ Explosion-proof designs can be used in hazardous area of industrial sites.
    • ☆ Low maintenance cost, easy to update and improve.
  • E502-UV/IR2 Explosion-Proof UV/IR2 Flame Detector

    ☆ AS-E502-UVIR2 flame detector provide a new generation of fire detection capability and technical standards.

    ☆ AS-E502-UVIR2 flame detector adopts a specially designed “Daylight-blind” UV photoelectric sensor and a newly narrow-band current infrared pyroelectric sensor, which can effectively distinguish the real flame radiation and interference sources.

    ☆ AS-E502-UVIR2 flame detector is built-in a 32-bit microprocessor and patented signal processing algorithm, it can detect flame signals quickly, reduce response time, increase detection accuracy, reduce false alarm rate.

    ☆ AS-E502-UVIR2 flame detector maintains the performance of explosion-proof, protection, corrosion resistance.

    ☆ AS-E502-UVIR2 flame detector is smaller, lighter, more convenient to install comparing to our old version detector.

    ☆ Built-in 32-bit high-speed, low-power, high-performance, high-precision data processing chip.
    ☆ Adopt patented and fast response UV optical sensor and a newly narrow-band current infrared pyroelectric sensor.
    ☆ A small fire can be detected earlier.
    ☆ The detection distance is 35 meters (0.33m*0.33m*0.05m n-heptane fire).
    ☆ The perfect algorithm combines optimally the flame detection and false alarm capabilities.
    ☆ Detector is fit to a variety of fuels.
    ☆ Apply to heavy industry applications.
    ☆ Explosion-proof designs can be used in hazardous area of industrial sites.
    ☆ Low maintenance cost, easy to update and improve.

  • End Water-test Equipment

    End Water-test Equipment
    End Water-test Equipment installs at the end of the network or partition networks system, inspection system start, alarm and linkage, and other functions of the device. End Water-test Equipment installs at the end of the network or partition networks system, inspection system start, alarm and linkage, and other functions of the device.

    Product features : 
    Test device from the table before the valve, pressure gauge, testing the waters joint, etc.
  • Explosion proof emergency start / stop-action button AW-D136EX

    Explosion proof emergency start / stop-action button AW-D136EX
    Explosion proof emergency start /stop action button is a kind of non-coding manual alarm button switch , which explosion proof performance in line with GB3836-2000 series of standards, inspected by the state designated inspection units, and acquired explosion proof certificate. Emergency start/ stop action button is available in 1 and 2 Zone hazardous locations which include Class Ⅱ A, B, C class T1 ~ T6 temperature group explosive gas environment.

    Explosion proof emergency start / stop button is a indispensable equipment in explosion proof fire alarm system ,consist with the fire alarm control panel and other equipment to be fire alarm system. When the protection area is in fire, press the emergency start button to send a signal to the gas fire control panel, control panel emit gas extinguishing gas spray command, by the delay, start spraying the gas solenoid valve. During the delay, if the site staff confirmed that no fire occurs, press the emergency stop button immediately move to terminate the start.

    Product features :

    1. Explosion proof emergency start / stop button is beautiful appearance, compact
    structure, stable and reliable performance.
    2. In order to avoid misuse, explosion proof emergency start / stop button use glass to protect the device, when the fire broke out press corresponding button after breaking the glass. Please replace the glass after using.
    3. Explosion proof emergency start / stop button can be used with fire alarm control panel of any domestic and foreign manufacturers.

  • Explosion Proof Fire Strobe AW-CSS2166EX

    Lampu Strobo Api Explosion Proof AW-CSS2166EX

    Lampu strobo api tahan ledakan (explosion proof) adalah lampu alarm non-kode, yang kinerja tahan ledakannya sesuai dengan seri standar GB3836-2000, yang diperiksa kelayakannya dan memperoleh sertifikat bukti ledakan. Lampu strobo api explosion proof cocok untuk industri dengan lokasi berbahaya (hazardous area) zona 1 dan 2 yang mencakup lingkungan dengan muatan gas eksplosif pada kelompok suhu Kelas Ⅱ A, B, C kelas T1 ~ T6.

    Lampu strobo api explosion proof AW-CSS2166EX tidak hanya berlaku untuk semua produsen switchboard fire telephone multi-channel, tetapi juga berbagai jenis sakelar yang dikendalikan program terpasang saat ini. Ketika site lokasi mengalamai kebakaran, panel kontrol alarm kebakaran akan mengirimkan sinyal untuk mengaktifkan sirkuit alarm. Untuk mencapai tujuan untuk mengingatkan personel situs, sinyal alarm ringan dikeluarkan.

    Fitur produk:

    1. lampu strobo api explosion proof dapat digunakan bersama dengan tombol alarm manual untuk mencapai tujuan alarm yang sederhana dan ringan.
    2. lampu strobo api explosion proof dapat digunakan dengan panel kontrol alarm kebakaran dari produsen dalam dan luar negeri.
    3. sumber cahaya strobo api explosion proof dibuat oleh banyak kombinasi lampu LED ultra-terang. Sehingga memiliki tampilan yang menarik, umur pemakaian yang panjang dan konsumsi daya yang rendah.

  • Explosion Proof Manual Call Point AW-D135EX

    Model AW-D135EX
    Voltage DC24V
    Alarm Current 10mA
    Indicator Standby: Green       Alarm: Red
    Alarm Out Normal Open
    Ex-Atex Protection Level Exd II CT6
    Mating Host AW-CFP2166 fire alarm control panel
    Outlet Thread G20
    Environmental Temperature range: -20 to 50°C
    Humidity: 5 to 95% RH, non-condensing
    Materials and colors Cast IronABS, RED
    Size 135mm* 130mm* 64mm
    Weight about 1kg

     

  • Explosion Proof Safety Barrier AW-D137EX

    Explosion Proof Safety Barrier AW-D137EX
    Explosion proof barrier is a kind of non-coding Explosion proof barrier , which performance is in line with GB3836-2000 series of standards, inspected by the state designated inspection units, and acq…uired explosion proof certificate. Barrier is available in 1 and 2 Zone hazardous locations which include Class Ⅱ A, B, C class T1 ~ T6 temperature group explosive gas environment.
    Product features :

    Explosion proof barrier does not affect the normal operation of electrical equipment under normal circumstances, when the system fails, it can limit energy (electric power) that turn into dangerous place to a safe value. This product can be used with a variety of fire detectors, buttons and other electronic products. This product uses an advanced resistive, transistor dual electronic switching circuit, fast starting speed, extremely small output resistance, automatic recovery when the current or voltage input exceeds a predetermined value, the barrier start working, so that the output voltage is approximately zero, the current is reduced to a safe value.

  • Explosion Proof Three Infrared Flame Detector AW-FD708EX

    Explosion Proof Three Infrared Flame Detector AW-FD708EX
    The detector AW-FD708EX combines the three infrared band sensor and advanced flame analysis technology, to eliminate false alarm and improve detection range, and can apply to most commonplace(Pipeline, Electrostatic Paint, Printing, Warehousing and etc).
    Product features :
    • Reliable fault diagnosis
    • Built-in high-speed, low-power, high-performance 32-bit high-precision data processing chip;
    • Adopt patented narrow band current infrared pyroelectric sensor;
    • A small fire can be detected earlier;
    • The perfect algorithm best combines flame detection and false alarm capabilities;
    • The detector is suitable for a variety of fuels;
    • It’s suitable for heavy industrial applications;
    • It’s low maintenance cost and easy to update and improve.

    Detection Range

    Fire Source and Size

    Details

     

    Maximum Distance

    N-Heptane

    0.3×0.3m

    40m

    Gasoline

    0.3×0.3m

    35m

    Diesel

    0.3×0.3m

    35m

    Alcohol

    0.3×0.3m

    30m

    Kerosene

    0.3×0.3m

    35m

    Methane

    0.5×0.2m

    30m

    Paper

    0.3×0.3m

    30m

    Respond Time

    N-Heptane

    <10s

  • Fire Hose

    Product features:

    Fire hose is mainly used for when the fire broke out, with a fire hose led by water from a fire hydrant, connected to the fire, put out the fire.

  • Fire hose rack cabinet

    Asenware offers fire hose with cabinets with
    several mounting options. Suitable for buildings,
    hospitals , hall , malls , stages etc.
    Product features

    • Immediate water supply from the source• Suitable for Class II fire as per NFPA standard ( trained personal or fire department )
      • Single Person Operation at 100 GPM at 65 PSI (375 LPM/4.5 Bar)

      Hose Rack Assembly
      – Type: Swing-out L-shaped Arm, Pin Type Rack Red Enamel Steel
      – Hose40 mm x 30 m (1.5″ x 100′) Length Collapsable Single Jacket 100% Synthetic
      – with Rocker Type 40 mm (1.5”) Coupling
      – Nozzle40 mm (1.5″) Plastic Fog Type
      – Valve Control40 mm (1.5″) Cast Brass Angle Valve

  • Fire Pump Set

    ​AW series fire pump set is mainly installed in a fire truck, fire extinguishing system or other fire control facilities, used for conveying liquids such as water or foam solution agent special pump.
    Specification:
    Fire pump system is made of E+D+J
    Operation:1 Duty(electric)+1 standby(diesel engine)+1 jockey
    Capacity:30 to 2000 GPM with pressure 4 to 20 bar
    Pressure vessel:25,50,75,100…Liters, pressure will be 0.6mpa,1.0mpa,1.6mpa,select according to pump head.
    Speed:740-3000 r/min


    Product features
    1. Application scope
    Equipment for warehouses, docks, airports, petrochemical, power plants ,liquefied gas, textiles, ships, oil tankers and other occasions of fire service.
    2. Using instruction
    Altitude :<=1000m
    Ambient temperature:+5 -40 degrees Celsius
    Relative humidity: <=90%

     

  • Fire System Power Supply Box

    AS-PSU9A is an external power supply in a compact metal housing for holding up two 12V / 7 Ah batteries.

    It provides additional uninterruptible power for use in fire, security, alarm, access control, cctv systems.
    It is listed for indoor dry locations and can easily be installed where needed.
    Product Name
    Power Supply Box
    Model No.
    AS-PSU9A
    Input Voltage
    AC 220V / 50 Hz
    Output Voltage
    DC 24V
    Output Current
    9 AH
    Charging Voltage
    DC 27.6V / 1.5A
    Output Terminals
    Three 24V positive and negative poles
    Battery Terminals
    Battery + / –
    Cable Inlet
    Three pvc cable gland connector locknut
    Recommend Battery Type
    Lead-acid battery 2 PCS 24V / 7AH
    Type of Protection
    IP30
    Dimension
    Approx. L335 x H260 x W103 (mm)
    Operating Temperature
    -10℃ ~ +50℃
    Operating Humidity
    20% ~ 90% RH (No Condensation)
  • Flange Type Signal Gate Valve

    Flange Type Signal Gate Valve
    Signal gate valve can be used to control air, water, steam, all kinds of corrosive medium, mud, oil, liquid metal and radioactive medium such as various types of fluid flow. Signal gate valve opening and closing is ram, ram movement direction perpendicular to the direction of flow and the valve can only be fully open and close, not to adjust and throttling.
    Product features :
    1. Fluid resistance small, sealing surface of erosion and erosion by the medium.
    2. Open and close more effort.
    3. Medium flow direction is not restricted, disturbed flow, reduce the pressure.
    4. Shorter form, simple structure, good manufacturing technology, wide application scope.
    5. Made from light weight: ontology with senior black iron ball, compared with traditional gate valves, the weight about 20% ~ 20% reduction in weight, easy installation and maintenance.
    6. Flat type brake block: traditional gate often wash the tube in the water after the external objects such as stone, wood, cement, iron filings, sundry sedimentation on the bottom of the valve such as the slots, easy to cause cannot close tightly and form slack phenomenon, at the bottom of the seal of the elastic base seat gate valves with water pipe with flat design, not easy to cause debris deposition, make the flow unimpeded.
  • Flexible Connection

    Flexible Connection
    Flexible joint is made up of fabric reinforced rubber pieces of rubber and flat shape union, loose tube of metal flanged or threaded flange, used for pipeline vibration isolation noise reduction, comp…Flexible joint is made up of fabric reinforced rubber pieces of rubber and flat shape union, loose tube of metal flanged or threaded flange, used for pipeline vibration isolation noise reduction, compensation displacement of the joint.

    It is a kind of high elasticity, high air tightness, medium resistance and weatherability of pipe joint.

    Product features : 

    1, Small volume, light weight, good elasticity, easy installation and maintenance.
    2, The installation time can produce transverse, axial, angular displacement, pipe impassability heart, flange unparallel restrictions.
    3, The structure of the work can reduce the noise, vibration absorbing ability

  • Foot Valve

    Foot Valve
    Foot valve by valve body, valve cover, valve, such as parts, gasket seal ring and bottom valve disc with single and double disc and disc type.Foot valve by valve body, valve cover, valve, such as parts, gasket seal ring and bottom valve disc with single and double disc and disc type.

    Bottom valve after the access to the pipeline, the liquid medium to enter the body from the bonnet direction, the pressure of the liquid on the disc, that allows the medium flows through the valve is opened。

    When the body within the medium pressure change or disappear , the disc will be closed to prevent backflow medium.

    Bottom valve is mainly used in processing of grout mechanical equipment such as pump, usually bottom valve can be installed in the bottom of the suction pump water, to prevent the reverse flow of grout.

    Product features : 

    1. Bottom valve is a kind of energy saving valve, generally installed in the bottom of the suction pump water, limit the fluid pump tube return water sources, plays not only the function.
    2. That has many water inlet valve cover and stiffener, has played a difficult clogging, mainly used in the pipeline pump.
    3. Waterway and supporting role.
    4. Diameter more than single, double disc, disc type, with flanges connection and screw thread connection.

  • FSP1006 Gas Extinguishing Control Panel

    Products Features

    AS-FSP1006 is a conventional fire Fighting and detection control panell designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire fighting & alarm control panel
    4 Detection Zones Panel, 1 Fire Fighting Area, 20 to 32 Detectors per Zone
    Relay output for fire condition, Relay output for double knock condition
    Zones Fault LEDs indication, Status for all steps of fire fighting Fault Relay Output, Auxiliary Output for 28 Volts
    Sound output for Alarm & firefighting Condition
    Up to 8 repeaters can be connected to one panel
    Switched mode power supply 24 V,3A with 2 battery chargers 12V
    End of Line Status Detection, Short circuit /open circuit detection
    Release switch for gas release, Manual automatic switch control
    Hold Switch, Enable / Disable key switch

  • GRS Gas Release Warning Signage

    Through controller to make it work, said gas spraying, remind personnel shall not enter areas of gas fire extinguishing.
    Work, flashing shows “GAS” may not be entered in red words.
    Spraying indicator is gas fire extinguishing system of supporting products, usually installed at the entrance of the protected sites.When spraying gas, gas fire extinguishing controller (hereinafter referred to as “controller”) will start the spraying lamp light instructions, to remind people pay attention to and take corresponding measures.Spraying the lamp with gas fire extinguishing system for the controller.
    Gas spraying light communicate with the controller USES the digital signal, work stable and reliable, and has good inhibition to electromagnetic interference.

    Parameter

    • Operating Voltage: DC24V/AC24V
    • Non-polarized Working Current: ≤70mA @ 24 VDC
    • Flash Period: 1.2-1.5 Sec.
  • GST102 Infrared Reflective Beam Smoke Detector

    Conventional Reflective Beam Detector (hereinafter called the detector) is a non addressable reflective infrared beam smoke detector, which must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector.
    With excellent built-in microprocessor, the detector has strong ability of analysis and
    judgment. The detector can automatically carry out system adjustment, compensation
    of variation of ambient data, and judgment of fire and fault through fixed algorithm, and

    indicate these states by LED and signal output terminals. With new and reasonable design, attractive appearance, flexible adjustment and alignment method it’s easy to install and adjust. The sensitivity of the detector can be set through hand held programmer in field, decreasing the demand for cleanliness of field conditions, and enlarging application areas. The detector is applicable to historical buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons etc, as well as places where slight smoke particles exist.

    Parameter:

    • Operating Voltage: 15VDC-28VDC
    • Sensitivity Level: Level 1: High sensitivity.  Level 2: Medium sensitivity.
    • Monitoring Area: aximum monitoring area: 14*100=1400m2  Maximum width: 14m
    • Length of Optical Pathway: 8m-100m
    • Dimension: length: 206mm width: 95mm thickness: 95mm
  • HD105 Heat Detector

    AS-HD105 Heat detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

    Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

    The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

    Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.

    Product Features:

    • Operating Voltage Range: 9 to 28VDC Volts Non-polarized
    • Standby Current: 60μA @ 24 VDC
    • Installation Temperatures: -10°C to50°C
    • Operating Humidity Range:  ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
    • Maximum Alarm Current (LED on: ) ≤ 30mA @ 24 VDC
    • Fixed Temperature Rating: 57°C
    • Height: 48mm installed in Base
    • Diameter: 99mm
    • Weight: 155g
  • HD802EX Explosion Proof Heat Detector

    Detektor panas (heat detector) explosion proof AS-HD802EX adalah detektor tipe konvensional dengan output relai, yang kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Bagian penginderaan suhu detektor menggunakan sensitivitas elemen peka suhu untuk mendeteksi suhu sekitar, sangat cocok untuk tempat di mana ada kenaikan suhu yang signifikan saat terjadi kebakaran.

    Detektor panas (heat detector) explosion proof AS-HD802EX mengadopsi desain yang unik untuk mencegah serangga, debu, dan cahaya eksternal. Dengan struktur baru, kinerja yang andal, dan ketahanan terhadap kelembapan yang kuat.

    Detektor panas (heat detector) explosion proof AS-HD802EX telah dilengkapi dengan penghalang keamanan. Penghalang keamanan mengadopsi sirkuit sakelar elektronik ganda resistif dan transistor, yang memiliki kecepatan awal yang cepat dan dapat dipulihkan secara otomatis.

    Ketika suhu alarm mencapai ambang batas yang telah ditetapkan, indikator detektor menyala, kontak NO tertutup, kontak NC terbuka, sinyal alarm kebakaran akan dikirim ke panel kontrol utama. Detektor akan dipulihkan hanya jika sistem diatur ulang (atau dimatikan lalu dihidupkan).

    Detektor panas (heat detector) explosion proof AS-HD802EX berlaku untuk Zona 1 dan Zona 2 di area dengan persyaratan tahan ledakan di industri perminyakan dan kimia

    Type
    Explosion Proof
    Operating Voltage
    24VDC
    Standby Current
    ≤60μA
    Alarm Current
    ≤10mA
    Explosion Proof Mark
    Exd (ib) IICT6
    Power-on time
    ≤30s
    Alarm temperature
    57℃
    The Ambient Temperature
    -10 ° C ~ +55 ° C
    Relative Humidity
    ≤95% (non-condensing)
  • Hose Reel

    Self-help type fire hose reel is shopping mall, hotel, warehouse and residential places such as the preferred equipment. By the valve, input line, spokes, supporting frame, rocker arm, hose and spray gun parts, such as water for fire extinguishing agent, can be in the process of the hose on fast injection agent fire extinguishing apparatus. General installation in indoor fire hydrant cabinet, is a new type of indoor fixed fire protection system.

    Product features:
    General installation in indoor fire hydrant cabinet, is a new type of indoor fixed fire protection system.

  • IRBD Reflective Beam Smoke Detector

    1. AS-IRBD Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning.

    2. The AS-IRBD has four adjustable operational ranges of between 8 to 20, 20 to 40, 40 to 70 and 70 to 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB, 3.8dB and 5.8dB to meet the specific environmental requirement.

    3. The AS-IRBD works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflector, it will notify the fire alarm panel when the infrared beam is obscured by smoke.

    4. The AS-IRBD is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.
    Features:
    1. EN54-12 Compliance.
    2. Hassle free alignment, built with digital guide display and laser beam pointing.
    3. Employ single-ended design through reflective mirror.
    4. Four ranges wide monitoring from 8-100 meters via encoder.
    5. Three users programing sensitivity adjustment.
    6. Built-in microprocessor.
    7. Self-diagnosis function can monitor for internal faults.
    8. Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter.
    9. Fire and Fault interfacing relays.
    10. Attractive and pleasing appearance.
    11. Real User friendly alignment method.
  • Main Relief Valve

    Main Relief Valve
    Main Relief Valve is mainly used in high-rise building fire test cycle system pressure, to prevent the excessively high hydraulic system failure. Working principle of a pressure relief valve, relief valve principle is that when the pipeline pressure is greater than the pressure relief valve set pressure, there will be pressure relief valve in the oil flow, so as to control the pressure in the pipeline will not exceed a certain limit.
    Product features :
    Pressure relief valve by the main valve, pressure relief/holding pressure pilot valve needle valve, ball valve, micro shape filter and pressure gauge of hydraulic control of system.Use of hydraulic automatic operation, can make the pressure release valve and can be used for holding pressure valve.As a pressure relief valve, it can maintain water supply way pressure under the TVC of set;For holding pressure valve, can maintain the main valve upstream water pressure above the set value, maintain the main valve upstream water supply pressure.
  • MCP-05 Manual Pull Station

    AS-MCP-05 conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So AS-MCP-05 conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system.

    The manual call points provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.

    Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word “ACTIVATED” appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.

    Resetting the station is simple: insert the key, twist one quarter-turn, then open the station’s front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station’s front cover, which automatically resets the switch.

    Product Features:

    • Operating Voltage Range:928VDC Volts
    • Alarm Current:45 mA @ 24 VDC
    • OperatingHumidityRange:10% to 93% Relative Humidity, Non-condensing
    • OperatingTemperatureRange:-10°Cto50°C(14°Fto122°F)
    • Dimensions:Length140mm, Width105mm, Depth45mm
    • Weight:Net Weight220g
  • MCP-2D Manual Call Point

    This kind of manual call point is usually stalled at the entrance and exit place,the people on site will push the button to send an alarm signal to control center in case of emergency. When the control center receives this signal,it will shows the serial number or place where the signal comes from.thus security or other people will act upon alarm.it is suitable for hotel,restaurant,machine room,bank,warehouse,museum,library,office,etc

    Product Features:

    • Rated voltage:12-24VDC
    • Standby current:≤330uA (DC24V)
    • Alarm Current:≤35mA (DC24V)
    • Power Indicator: Green Led
    • Alarm Indicator: Red Led
    • NO/NC: Optional
    • Products Sizes: 86x86x60mm
  • MCP-EW Manual Call Point Weather-proof Enclosure

    MCP-EW manual call point enclosures provide a weather proof enclosure for ANSORL manual call points.
    Access to the manual call point is provided by an easy-to-operate Lock, to unlock the hinged transparent cover.
    The weather proof enclosure provides fire detection and alarm system designers with a premium solution for outdoor life safety and property protection applications.

    Products Features

    • Robust enclosure
    • IP-X8 rating
    • Suitable for outdoor use
    • Compatible with ANSORL manual call points
    • Easy installation
    • Low maintenance
  • MCP01EX Explosion Proof Manual Call Point

    Manual call point explosion proof AS-MCP01EX adalah perangkat tipe konvensional dengan output relay, kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Manual call point explosion proof AS-MCP01EX adalah perangkat penting dalam penggunaan sistem alarm kebakaran. Ketika terjadi kebakaran, orang mengkonfirmasi insiden kebakaran dan menekan tombol alarm manual, setelah diaktifkan, sinyal alarm kebakaran akan dikirim ke panel kontrol, yang akan memberikan alarm visual dan audio untuk memperingatkan orang untuk evakuasi.

    Manual call point explosion proof AS-MCP01EX memiliki fungsi mengunci sendiri dan dengan kunci khusus untuk mengatur ulang, yang dirancang untuk memenuhi persyaratan standar nasional.

    Manual call point explosion proof AS-MCP01EX memiliki indikator LED kembar. Saat perangkat dalam status kerja normal, lampu indikator LED hijau menyala, saat perangkat dalam status alarm (diaktifkan), lampu indikator LED merah menyala.

    Manual call point explosion proof AS-MCP01EX sesuai dengan standar GB3836-2010 untuk mekanisme explosion proof. Titik manual call point explosion proof digunakan untuk Zona 1 dan zona 2, yang berisi dengan gas eksplosif pada suhu kelas II B dan II C T6

     

    Type
    Explosion Proof
    Power Supply
    24VDC
    Contact Capacity
    Normally open 0.5A
    LED Indicator 1
    Green (working)
    LED Indicator 1
    Red (alarm)
    Explosion Proof Mark
    Exd IICT6
    Atmospheric Pressure
    80~110KPa
    The Ambient Temperature
    -20° C ~ +50° C
    Relative Humidity
    ≤95% (non-condensing)
  • MN3010 Addressable 1 Loop Fire Alarm Control Panel

    MN3010 fire alarm control panel (here in after referred to fire control unit) is a newgeneration of fire alarm control panel launched by ANSORL .
    In order to meet the engineering design demand, the control unit is provided with bothlinkage and control functions.
    It can support uses of other related products of the Company toform an integrated alarm and linkage control system, which is perfectly suitable for the application of small and medium-sized fire alarm and firefighting and linkage integrated control system.
    The fire alarm linkage control system is widely used in small and medium-sized firefighting engineering, such as high-grade office building, residence community, department store, gymnasium, exhibition room, library, workshop, supermarket and hotels.
    • 1. Adopts the latest generation of high-speed microprocessor. Data processing rate and data storage capacity reach 100-fold and 1000-fold increase, respectively, compared to traditional technologies.
    • 2. MN3010 is provided with 4.3″ color display screen (LCD), with a display resolution of
      430×272.
    • 3. The operation interface imitates Windows menus and window interfaces and is almost the same as the computer operating and using habits, thus facilitates the learning.
    • 4. Operation and control are flexible and convenient through the standard USB-interfaced
      computer keyboard and mouse + the panel buttons are used as field programming devices.
    • 5. T9 pinyin input method is provided and texts can be input easily and freely.
    • 6. Use smart U disk (optional), which can be used to copy or restore setup file and historical file of the system, thus facilitating the system maintenance.
    • 7. It adopts the non-polarity two-bus intelligent alarm linkage pattern and can connect 324
      intelligent detectors or intelligent modules at most. The addresses of module detectors can
      be mix-programmed (optional 1-324).
    • 8. It supports interconnection of 20 MN3010 control units and the maximum system capacity after networking reaches 20×324=6480 (alarmpoint).
    • 9. The maximum capacity of linkage control unit of a single equipment: 10 points.
    • 10. The system has the function of recording operation history: 1000 pieces of historical fire alarms, historical requests, historical feedbacks, historical faults and historical operations, respectively.
    • 11. The user may customize the equipment type, which can facilitate the system integration.
    • 12. It has the modular manual single-point start/stop functions, which can facilitate field
      debugging and testing.
    • 13. It has the single-point detector/module testing function, the detector working status and test data are clearly displayed.
    • 14. The system is provided with a dedicated mini-printer as standard, which is used to print various operating statuses of the system immediately.
    • 15. It can be accessed with area indicating panels, building indicating panels and floor indicating panels, which will extend display information of the control unit to corridor and other locations.
    • 16. It can be connected with PC to achieve city networking.
    • 17. The system carries out the hierarchy management of multi-level users and the users of
      different levels are granted with corresponding operating system permissions, which is
      convenient for system management.
    • 18. It is possible to update the system on field or remotely to ensure the system operates stably and reliably.
  • MRS Manual Release Station

    Manual Release Station is a device type of fire alarm system, when the staff fire without fire detector to detect fire personnel manual manual alarm button, report the fire signal.

    Product Features:

    Function: report of fire signals;
    Start method: manual press;
    The Manual release is connected with Fire fighting panel;
    There are three buttons on the station, one is START button, and another one is STOP button. When the START button is pressed, you can press RESTORE button to restore the start button.

  • MTS Maintenance Switch

    Parameter

    • Operating voltage: DC24V
    • Switch rated: 5A 250VAC
    • DC rating : 5A up to 30VDC
    • LEDS rated :10mA each for a total current draw of 20mA.
  • Non-rising System Gate Valve

    Non-rising System Gate Valve
    Gate valve can be used to control air, water, steam, all kinds of corrosive medium, mud, oil, liquid metal and radioactive medium such as various types of fluid flow.
    Product features :
    1, Small flow resistance.
    2, More energy when opening and closing.
    3, Height, opening and closing time is long.
    4, Water hammer is not easy to produce.
    5, Medium can be on both sides to any direction, easy to install.
    6, The structure length (the distance between the two connection end face shell) is smaller.
    7, The structure of the form is simple, short length, good manufacturing technology, wide application scope.
    8.Compact structure, the valve rigidity, smooth channel, number of flow resistance is small.
    9. The sealing surface of stainless steel and carbide, long service life;
    10.Using PTFE packing, sealing is reliable. The flexible operation of the light.
  • Non-rising System Gate Valve

    Non-rising System Gate Valve
    Gate valve can be used to control air, water, steam, all kinds of corrosive medium, mud, oil, liquid metal and radioactive medium such as various types of fluid flow.
    Product features :
    1, Small flow resistance.
    2, More energy when opening and closing.
    3, Height, opening and closing time is long.
    4, Water hammer is not easy to produce.
    5, Medium can be on both sides to any direction, easy to install.
    6, The structure length (the distance between the two connection end face shell) is smaller.
    7, The structure of the form is simple, short length, good manufacturing technology, wide application scope.
    8.Compact structure, the valve rigidity, smooth channel, number of flow resistance is small.
    9. The sealing surface of stainless steel and carbide, long service life;
    10.Using PTFE packing, sealing is reliable. The flexible operation of the light.
  • OS&Y Gate Valve

    OS&Y Gate Valve
    Gate valve can be used to control air, water, steam, all kinds of corrosive medium, mud, oil, liquid metal and radioactive medium such as various types of fluid flow.
    Product features :
    1, Small flow resistance.
    2, More energy when opening and closing.
    3, Height, opening and closing time is long.
    4, Water hammer is not easy to produce.
    5, Medium can be on both sides to any direction, easy to install.
    6, The structure length (the distance between the two connection end face shell) is smaller.
    7, The structure of the form is simple, short length, good manufacturing technology, wide application scope.
    8.Compact structure, the valve rigidity, smooth channel, number of flow resistance is small.
    9. The sealing surface of stainless steel and carbide, long service life;
    10.Using PTFE packing, sealing is reliable. The flexible operation of the light.
  • Pressure Switch

    Pressure Switch
    Pressure switch is pressure change of water pressure can be converted to electrical signal output facilities. Pressure switch is pressure change of water pressure can be converted to electrical signal output facilities.Used to start the spray pump, monitoring the working state of alarm valve and the pressure inside the pipeline.
    Ontology by the copper alloy, aluminum alloy bearings, the copper alloy valve core, d eyes of rubber sealing film and micro switch.

    Product features :
    1. Should be installed vertically upward.
    2. Interface: R1/2 “.
    3. The working medium: water, air.
    4. Connection cable should wear inside and outside the galvanized steel pipe.
    5. Wiring: provide can pay a normally open contacts with a normally closed contact, for users to choose to use.

     

  • RIL-06 Remote LED Indication

    This remote led indicator is an warning device used in installation where a detector goes to alarm is likely to occur behind a locked door, inaccessible rooms, or in a ceiling void to provide indication of the activation of a fire detector. The indicator’s design widely applies to all kinds of commercial constructions requiring a local visual indicator such as process control, security and shut down operations, with its high reliability and ease of installation.

    Technical Parameters

    Working voltage: 3VDC or 24VDC.
    Working current: ≤10mA.
    Flash frequency: about 80 times/min.
    Operation temperature: -10℃ to 55℃.
    Operation humidity: ≤95%RH (no condensation).
    Alarm indicator: LED flash in red lighting.
    Dimension: 85 x 85 x35 mm.

  • Rubber Disc Check Valve

    Rubber Disc Check Valve
    Check valve flow refers to rely on the media itself, and automatic opening and closing valve, used to prevent the backflow medium valve. Also known as the non-return valve, check valve, valve, and the back pressure valve upstream.Check valve belongs to a kind of automatic valve, its main role is to prevent the backflow medium, to prevent the pump and drive motor reversal, and the discharge of the container medium.
    Produt features :
    1. Bolted bonnet, swing and elevating disc metal sealing surface.
    2. Body and bonnet joint form.
    3. Bolted bonnet, the flange gasket type can undertake choosing according to difference of stress level.
    4. Disc spacing device, prevent disc open position is too high to be shut down.
    5. Solid pin shaft installation precision, high strength, to ensure the use performance and service life of the valve.
    6. Rocker has enough strength, close enough freedom to facilitate the disc to close.
    7. Disc has sufficient strength and rigidity, clapper sealing surfaces according to user requirements surfacing welding metallic materials or non-metallic materials.
  • Saddle type water flow indicator

    Saddle type water flow indicator
    Saddle type water flow indicator is part of the automatic sprinkler system.Using the spray pipe network in the inland waters flow pushing blade, touch the micro switch, so as to convert current signal into electrical signal connected to the controller to start the automatic fire alarm system is a kind of alarm devices, and can be used to detect the automatic sprinkler system and to determine the fire area.

    Risk is widely used for medium and light construction water level blazes hotels, shopping malls, restaurants, entertainment venues, hospitals, office buildings and factories, warehouses and other places.

    Product features :

    It can be installed on the main water supply pipe or bar conduit, given a certain regional small water flow of electrical signals, the signal can be sent to the electric cabinet, can also be used to start the fire pump control switch

  • SCO601M 220V+9V Standalone Smoke/CO Detector

    This product is a compound smoke and carbon monoxide detector, adopting photoelectric smoke detection and carbon monoxide high-performance electronic chemical sensor detection technology.It can real-time monitoring to detect the presence of smoke, detection of visible particles (smoldering fire) speed is quicker than the ionization smoke
    detector, also can real-time detect carbon monoxide. It is high stability, low power consumption, low sensitivity drift, etc. Once detecting the fire danger and carbon monoxide , alarm immediately red LED indicator light flashing quickly, and alarm, timely remind you and your family.

    Parameter:

    Working voltage : AC 220V, DC9V for electricity
    static current: <20uA (DC9V)
    alarm current: < 50mA (DC9V)
    Alarm output : sound and light alarm
    Alarm sound pressure: 85 db / 3 m
    The sensitivity of carbon monoxide: 30 PPM, within 120 minutes not alarm; 50 PPM, alarm within 60-90
    minutes;100 PPM,alarm within 10 to 40 minutes; 300 PPM, alarm in 3 minutes;
    Smoke: 1% ~ 5% / FT OBS
    Work environment : – 10 ℃ to + 50 ℃ (5% – 85% RH)
    Product size Φ 130 * 45 mm
    standard: CE&EN 14604 & RoHS

  • SCO701A Standalone CO Detector

    This product is of high stability voice type carbon monoxide detector(hereinafter referred to as detectors),using for detecting carbon monoxide gas leakage, carbon monoxide detectors selected advanced electrochemical sensors; with high stability, small sensitivity drift characteristics. This Products using digital backlit LCD to display alarm levels, when the detector detects CO leaks and carbon monoxide concentration reaches to the alarm setting, the detector LED flashes red and alarm sounds This product Is used In place may produce carbon monoxide.

    Parameters:

    • Operating Voltage Range: DC4.5V (3pcs AA Batteries)
    • Standby Current: ≤25uA
    • Alarm Current: ≤520mA
    • Operating Humidity Range: 0 to 90% Relative Humidity, Non-condensation
    • Operating Temperature Range: 0℃ to 40℃
    • Warm-up Time: 30s
    • Sound Pressure Level: ≥85dB/m
    • Size: 100x40mm
  • SD102 Smoke Detector

    AS-SD102 smoke detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

    Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

    The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

    Product Features:

    • Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
    • Standby Current: ≤60μA @ 24 VDC
    • Maximum Alarm Current (LED on: ) ≤ 30mA @ 24 VDC
    • Operating Humidity Range:  ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
    • Operating Temperature Range: -10°C to 50°C
    • Adjustable Sensitivity: 0.15-0.3dB/m
    • Height: 48mm installed in Base
    • Diameter: 99mm
    • Weight: 155g
  • SD801EX Explosion Proof Smoke Detector

    Detektor asap explosion proof AS-SD801EX adalah detektor tipe konvensional dengan keluaran relai, kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Detektor asap explosion proof AS-SD801EX mengadopsi teknologi hamburan baru dan perangkat optoelektronik yang diimpor untuk meningkatkan keandalan, stabilitas, dan konsistensi sensor, serta mengadopsi desain labirin yang unik untuk mencegah perangkat dimasuki serangga, debu, dan cahaya eksternal. Dengan struktur baru, kinerja yang andal, dan ketahanan terhadap kelembapan yang kuat.

    Detektor asap explosion proof AS-SD801EX telah dilengkapi dengan penghalang keamanan. Penghalang keamanan mengadopsi sirkuit sakelar elektronik ganda resistif dan transistor, yang memiliki kecepatan awal yang cepat dan dapat dipulihkan secara otomatis.

    Ketika konsentrasi asap mencapai ambang batas yang telah ditetapkan, indikator detektor akan menyala, sinyal alarm kebakaran akan dikirim ke panel kontrol utama. Detektor akan dipulihkan hanya jika sistem diatur ulang (atau dimatikan lalu dihidupkan).

    Detektor asap explosion proof AS-SD801EX dapat digunakan di Zona 1 dan Zona 2 di area yang memiliki persyaratan explosion proof di industri perminyakan dan kimia.

    Type
    Explosion Proof
    Operating Voltage
    24VDC
    Standby Current
    ≤120μA
    Alarm Current
    10mA≤I≤30mA
    Explosion Proof Mark
     Exd (ib) IIBT6 / Exd (ib) IICT6
    Power-on Time
    ≤10s
    The Highest Wind Speed
    7.6m/s (1500fpm)
    The Ambient Temperature
    -10 ° C ~ +55 ° C
    Relative Humidity
    ≤95% (non-condensing)
  • SG01EX Fire Alarm Explosion Proof Strobe Sounder

    Lampu sounder strobe explosion proof AS-SG01EX adalah perangkat tipe konvensional dengan output relay, kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Lampu strobe sounder explosion proof AS-SG01EX adalah perangkat penting dari sistem alarm kebakaran. Saat terjadi kebakaran, panel kontrol menerima sinyal alarm dari detektor kebakaran atau titik panggilan manual, kemudian panel mengirimkan sinyal start ke lampu strobe, yang akan memberikan alarm suara dan visual.

    Lampu strobe sounder explosion proof AS-SG01EX memenuhi standar GB3836-2010 untuk mekanisme explosion proof. Lampu strobe explosion proof dibuat secara khusus untuk industri Zona 1 dan zona 2, yang berisi area berbahaya atmosfer gas eksplosif suhu kelas II B dan II C T6.

    Type
    Explosion Proof
    Power Supply
    24VDC
    Alarm Current
    ≤650mA
    Sound Intensity
    ≤110dB
    Flash Frequency
    60 Times/min
    Sound Type
    1 Types
    Atmospheric Pressure
    Exd (ib) II CT6
    The Ambient Temperature
    -20° C ~ +50° C
    Relative Humidity
    ≤95% (non-condensing)
  • SGD301 Stand-Alone Combustible Gas Detector

    Product Features:

    Operating Voltage: 220VAC
    Power Consumption: <2W
    Alarm Concentration: 10%LEL
    Level of Sound : 85dB
    With test button
    With time setting button
    With LED display
    With power, fault, alarm indictor
    With relay contact output
    With solenoid valve output
    Dimension: Length 100 x width 100 x height 36 mm

  • SHD109 Smoke/Heat Combined Detector

    AS-SHD109 Smoke&Heat Detector work perfectly with all conventional intelligent fire control panels

    This Conventional Multi-detector uses an intelligent optical sensing chamber and a thermal sensor at the same time to detect smoke and heat.

    This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels where it can work from 9Volts to 32V DC.

    It has two LEDS on each detector to provide a local 360° viewing alarm indication.

    It flashes every five seconds, indicating that power is applied and the detector is working properly.

    The LEDS latch on in alarm. LEDS will be off when a trouble condition occurs indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

    This detector supports External Remote indication LED.

    Product Features:

    • Operating Voltage Range:9 to 28VDC Volts Non-polarized
    • Standby Current:≤60µA @ 24 VDC
    • Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC
    • Operating Humidity Range:10% to 93% Relative Humidity, Non-condensing
    • Operating Temperature Range:14°F to 120°F (-10°C to 49°C)
    • Smoke  Sensitivity:1.06±.26%FT.
    • Fixed Temperature Rating:135°F (57°C)
    • Rate of Rise Detection:Responds to greater than 15°F/min
    • Height:2.2˝ (55 mm) installed in Base
    • Diameter:4.0˝ (103 mm)
    • Weight:5.5 oz. (155 g)
  • SHD803EX Explosion Proof Smoke and Heat Detector

    Sensor kombinasi detector asap dan panas explosion proof AS-SHD803EX adalah detektor tipe konvensional dengan output relai, kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Sensor kombinasi detector asap dan panas explosion proof AS-SHD803EX mampu mendeteksi asap atau panas. Alat ini mengadopsi teknologi hamburan baru untuk meningkatkan keandalan, stabilitas, dan konsistensi sensor asap, selain itu, alat ini juga dilengkapi dengan elemen peka suhu berkualitas tinggi untuk mendeteksi suhu sekitar.

    Sensor kombinasi detector asap dan panas explosion proof AS-SHD803EX dilengkapi dengan struktur baru, kinerja yang andal, dan ketahanan terhadap kelembapan yang kuat.

    Sensor kombinasi detector asap dan panas explosion proof AS-SHD803EX telah dilengkapi dengan penghalang keamanan. Penghalang keamanan mengadopsi sirkuit sakelar elektronik ganda resistif dan transistor, yang memiliki kecepatan awal yang cepat dan dapat dipulihkan secara otomatis.

    Sensor kombinasi detector asap dan panas explosion proof AS-SHD803EX dapat diterapkan di Zona 1 dan Zona 2 di area dengan persyaratan tahan ledakan di industri perminyakan dan kimia.

    Type
    Explosion Proof
    Operating Voltage
    24VDC
    Standby Current
    ≤120μA
    Alarm Current
    ≤30mA
    Explosion Proof Mark
     Exd (ib) IIBT6 / Exd (ib) IICT6
    Power-on Time
    ≤30s
    The Highest Wind Speed
    7.6m/s (1500fpm)
    The Ambient Temperature
    -10 ° C ~ +55 ° C
    Relative Humidity
    ≤95% (non-condensing)
  • Silent check valve

    Silent check valve
    Check valve flow refers to rely on the media itself, and automatic opening and closing valve, used to prevent the backflow medium valve. Check valve flow refers to rely on the media itself, and automatic opening and closing valve, used to prevent the backflow medium valve.

    Also known as the non-return valve, check valve, valve, and the back pressure valve upstream.Check valve belongs to a kind of automatic valve, its main role is to prevent the backflow medium, to prevent the pump and drive motor reversal, and the discharge of the container medium.

    Product features :
    1. Bolted bonnet, swing and elevating disc metal sealing surface.
    2. Body and bonnet joint form.
    3. Bolted bonnet, the flange gasket type can undertake choosing according to difference of stress level.
    4. Disc spacing device, prevent disc open position is too high to be shut down.
    5. Solid pin shaft installation precision, high strength, to ensure the use performance and service life of the valve.
    6. Rocker has enough strength, close enough freedom to facilitate the disc to close.
    7. Disc has sufficient strength and rigidity, clapper sealing surfaces according to user requirements surfacing welding metallic materials or non-metallic materials.
  • SIREN-EX Explosion Proof Alarm Siren

    Sirene alarm explosion proof AS-SIREN-EX adalah perangkat tipe konvensional dengan output relay, kompatibel dengan sebagian besar panel kontrol alarm kebakaran di pasaran.

    Sirene alarm explosion proof AS-SIREN-EX adalah perangkat penting dari sistem alarm kebakaran. Saat terjadi kebakaran, panel kontrol menerima sinyal alarm dari detektor kebakaran atau titik manual call point, kemudian panel mengirimkan sinyal start ke sirine, yang akan membunyikan alarm.

    Sirene alarm kebakaran tahan ledakan AS-SIREN-EX memenuhi standar GB3836-2010 untuk kinerja explosion proof. Sirene tahan ledakan berlaku untuk Zona 1 dan zona 2, yang berisi area berbahaya dengan atmosfer gas eksplosif bersuhu II B dan II C T6.

    Type
    Explosion Proof
    Power Supply
    24VDC
    Alarm Current
    ≤600mA
    Sound Intensity
    ≤110dB
    Sound Type
    3 Types
    Explosion Proof Mark
    Exd II CT6
    Atmospheric Pressure
    80~110KPa
    The Ambient Temperature
    -20° C ~ +50° C
    Relative Humidity
    ≤95% (non-condensing)
  • SPKR-EX Explosion Proof Horn Speaker

    Speaker explosion proof AS-SPKR-EX adalah speaker klakson volume tinggi tipe tekanan konstan, (tipe resistansi konstan dapat disesuaikan sesuai permintaan penggunaan).

    Speaker explosion proof AS-SPKR-EX cocok untuk dipasang di tempat-tempat yang mengandung bahan yang mudah terbakar atau meledak, misalnya di industri perminyakan, kimia, tekstil, militer, listrik, metalurgi, farmasi, dan industri lainnya. Item ini dapat digunakan dalam sistem amplifier public.

    Speaker explosion proof AS-SPKR-EX memenuhi standar GB3836-2010 untuk performa tahan ledakan. Speaker explosion proof berlaku untuk Zona 1 dan zona 2, yang berisi area berbahaya seperti area dengan gas eksplosif suhu kelasⅡB danⅡC T6

     

    Type
    Explosion Proof
    Power Supply
    AC70V/100V/110V/120V/220V
    Power Capacity
    5/10/15/25W
    Sound Intensity
    ≤ 100dB
    IP Protection
    IP65
    Explosion Proof Mark
    Exd II CT6
    Atmospheric Pressure
    80~110KPa
    The Ambient Temperature
    -20° C ~ +50° C
    Relative Humidity
    ≤95% (non-condensing)
  • SSD101 Stand-Alone Smoke Detector

    Standalone Photoelectric Smoke Detector can detect a large amount of smoke when fire generated sending alarm signal in time. Alarm adopts photoelectric smoke devices and excellent production technology, work stability, beautiful appearance, easy to install, without debugging, which can be widely used in hotels, stores, Internet cafes, dancing hall, coffee shop, lounge and residential places on fire safety monitoring.

    Parameter:

    Operating Voltage: 9V 6F22 Battery
    Static Current : ≤15uA
    Alarm Current : ≤56mA
    Alarm Output: Sound& Flash alarm, Wireless output 315MHz or 433MHz
    Level of Sound :≥85dB/m Detection garea: 40square meters when installation height between 6 to 12 meters.
    20square meters when installation height within 6 meters.

  • SSD221Y 10 Years Stand-Alone Smoke Detector

    Standalone photoelectric smoke detector (hereinafter referred to as detector) use high-performance ultra-low power consumption smart microprocessor working with the precise photoelectric sensor to process the collecting smoke concentration independently:Low-power consumption , stable performance, beautiful and durable casing. The smoke detector is powered by 1pc 3V CR17335 lithium battery, continuous for more than 10 years.This detector is widely used in internet bars, dancing halls, cafes, leisure rooms, residential areas etc.
    The detector is not suitable in the following locations:
    ●There is smoke under the normal circumstances.
    ●The place is dusty,misty,greasy or have corrosive gas.
    ●The relative humidity is more than 95% or the place is extremely cold or extremely hot.
    ●The ventilating speed is more than 5m /s

    Parameter:

    Power supply: 1PC 3V Cr17335 lithium battery
    Alarm sound pressure: 80dB at 3m straight ahead
    Battery life: 10 years
    Working environment: -10 ℃ ~ 50 ℃, <95% RH (no condensation)
    Output method: sound and flash

  • SSD331 Stand-Alone Smoke Detector

    Standalone Photoelectric Smoke Detector can detect a large amount of smoke when fire generated sending alarm signal in time. Alarm adopts photoelectric smoke devices and excellent production technology, work stability, beautiful appearance, easy to install, without debugging, which can be widely used in hotels, stores, Internet cafes, dancing hall, coffee shop, lounge and residential places on fire safety monitoring.

    Parameter:

    Operating Voltage : 9V 6F22 battery or DC12V
    Static Current : ≤15uA
    Alarm Current : ≤56mA
    Battery life : About 1 year
    Power Indicator : red LED
    Alarm Indication : red LED fast blink
    Level of Sound :≥85dB/m
    Operating temperature : -10℃~ +50℃
    Operating Humidity : ≤ 95 %RH

  • SSG-03 Strobe Sounder

    AS-SSG-03 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.

    The system designer must make sure that the total current drawn by the devices on the loop does not exceed the current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage.

    When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from electrical handbooks.

    Product Features:

    Work Voltage: 12/24VDC   Work Current: 100mA-150mA
    Flash Intencity≥1.2WS   Flash Period≤1.0S
    Provenience of sound alarm1.Ambulance sound 2. Sound of police car 3.Sound of fire truck
    Audio Alarm≥110dB
    Dimensions132x110x50mm

  • Trench type signal gate valve

    Trench type signal gate valve
    Signal gate valve can be used to control air, water, steam, all kinds of corrosive medium, mud, oil, liquid metal and radioactive medium such as various types of fluid flow. Signal gate valve opening and closing is ram, ram movement direction perpendicular to the direction of flow and the valve can only be fully open and close, not to adjust and throttling.
    Product features :
    1. Fluid resistance small, sealing surface of erosion and erosion by the medium.
    2. Open and close more effort.
    3. Medium flow direction is not restricted, disturbed flow, reduce the pressure.
    4. Shorter form, simple structure, good manufacturing technology, wide application scope.
    5. Made from light weight: ontology with senior black iron ball, compared with traditional gate valves, the weight about 20% ~ 20% reduction in weight, easy installation and maintenance.
    6. Flat type brake block: traditional gate often wash the tube in the water after the external objects such as stone, wood, cement, iron filings, sundry sedimentation on the bottom of the valve such as the slots, easy to cause cannot close tightly and form slack phenomenon, at the bottom of the seal of the elastic base seat gate valves with water pipe with flat design, not easy to cause debris deposition, make the flow unimpeded.
  • UFD Conventional UV Flame Detector

    The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response.

    It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored.

    The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by2Kgethanol in a Container of Base 33cmX33cm, Height5cm.

    Product Features:

    • OperatingVoltageRange:12 to 30 VDC Volts
    • Standby Current:≤10 mA @ 24 VDC
    • Alarm Current:≤30 mA @ 24 VDC
    • Spectrum:180~290nm
    • Detection Angle:110 degree
    • Detection Sensitivity:Grade I, 25m@flame
    • Relay Contact Load:1A@DC24V
    • Normal Status:LED blinking in 5 seconds interval
    • Alarm Status:LED lit steady
    • OperatingHumidityRange:10% to 93% Relative Humidity, Non-condensing
    • OperatingTemperatureRange:-10°Cto50°C(14°Fto122°F)
    • Height:1.8˝ (45 mm) installed in Base
    • Diameter:4.0˝ (103 mm)
    • Weight:5.4 oz. (153g)
  • Vent Valve

    Vent Valve
    Exhaust valve is applied to the independent heating system, central heating system, heating boiler furnace, central air conditioning, floor heating, solar heating system pipe exhaust, etc.

    Product features :

    Exhaust valve is applied to the independent heating system, central heating system, heating boiler furnace, central air conditioning, floor heating, solar heating system pipe exhaust, etc.

  • Wafer type signal butterfly valve

    Wafer type signal butterfly valve
    Signal butterfly valve is suitable for the petroleum, chemical, food, medicine, paper making  such as water and electricity, shipping, water supply and drainage, metallurgy, energy system piping.

    Available in a variety of corrosive, non corrosive gases, liquids semifluid and solid powder pipelines and containers used as adjustment and throttling device.Special is widely used in high-rise building fire control system and other need to display the state of the switch valve pipeline system.

    Product features :
    1, small, portable, easy disassembling and maintenance, and can be installed on any position.
    2, simple and compact structure, 90 ° rotating rapidly opening and closing.
    3, operating torque, energy saving and lighter.
    4, achieve completely sealed, the leakage test is zero.
    5, choose different parts material, can be used a variety of media.
    6, flow curve tending to straight line. Excellent regulation performance.
    7, the opening and closing test into more time, long service life.
  • Wireless Addressable Fire Alarm Control Panel

    AS-WFP Series Wireless Fire Alarm Control Panel’s typical configuration includes: main control panel, loop control panel, direct control panel, power supply etc.

    The control panel is small in size, convenient to install and simple to operate.
    It’s widely used in fire detection and fire fighting engineering.
    The fire alarm control system can be installed in small-scale fire safety projects such as high-grade office buildings, residential quarters, department, stores, gymnasiums, libraries, supermarkets, hotels etc.

    Main Power Supply
    AC220V (3.5A)
    Back-up Battery
    Lead-acid battery 12V/3.3Ah x 2pc
    Loop Capacity
    One loop 64 or two loops 128 points for option
    Radio Frequency
    Transmit Power <20dBm
    Frequency Band
    470MHz
    Communication Distance
    ≤700m
    Operating Temperature
    -10℃~+55℃
    Relative Humidity
    ≤95%
    Dimension
    360mm x 130mm x 480mm
  • Abort Switch Station AW-GD202

    The Manual release is connected with Fire fighting panel. There are two connectors. One is NC, and another one is NO.
    • Green: Connector(Dry NO)
      3A@AC220V 3A@DC30V

      Orange: Connector(Dry NC)
      3A@AC220V 3A@DC30V

  • Automatic Gas Extinguisher Control Panel AW-GEC2159

    The AW-GEC2159 Automatic gas extinguishing control panel is a combined fire alarm control panel and extinguishing system and has 4 detection zones…
    • Features: 

      1. Emergency stop: In delay time and found to have abnormal situation, does not need to start the fire extinguishing system, according to the manual control box or gas extinguishing controller of the emergency stop button, can prevent controller extinguishing instruction.

      2. Networking: Gas fire extinguishing controller also can connect with fire alarm controller, a remote control.
      3. Application:
      a)Electrical and electronic equipment;
      b) Can burn liquid and can melt the solid fire;
      c) Solid surface fire;
      d)Can cut off the gas source gas fire extinguishing before.

    Parameters:

    Wiring Diagram:

  • Automatic Gas Extinguisher Control Panel AW-GEC2169

    AW-GEC2169 with a new design, easy to operate, metal box opening and closing door with visible glass window, make the Panel running more safe,The automatic extinguisher control panel AW-GEC2169 is des..
    • The AW-GEC2169 automatic gas fire extinguisher panel has the following features:

      Alarm input : two alarming zone signal input , 16 detectors could be connected to each zone
      EM valve output : control the output of EM valve.
      Panel output: line fault output / alarm output / fire extinguishing signal output/24VDC output
      Power output: resettable 24VDC output, 200mA current limit protection
      Automatic power switching: 220V AC power and standby battery power can be switched automatically.
      Three levels of access control (view, operation, settings)
      Fault detection with display: Real-time detect working condition of input, output, system, power, ground, fuse,and so on.
      Manually disable function: Manually disable the Panel functions and zones devices.
      Evacuation: Manually activate the fire alarm devices.
      Silence operation: Manual silence the horns alarm and panel buzzer .
      Delay time setting: You can manual set the Panel reseting time and Release delay time.
      Panel Security Protection : outside cabinet with Visible glass window of opening and closing door .
      tability: long-term rigorous testing before leaving the factory, the Panel is stable, safe and reliable;

    AC INPUT 220VAC 50HZ +10%
    -15%
    DC OUTPUT at Power Board 24VDC (19V-28V) and 5VDC (4.9V-5.1V)
    Voltage for MCU 5V for power board MCU, 3.3V for others
    Current at 24VDC from PSE <450mA standby current
    Maximum current from PSE 1.4A except batteries charge
    Batteries current 1.85A maximum, current limited
    Auxiliary output 24VDC, 200 mA max, current limited
    Extinguishant release delay time Adjustable 0 to 60seconds(5 second steps)
    Imin, Imax.a and Imax.b according to EN54-2 Imin=340mA, Imax.a=424mA, Imax.b=1.4A
    Batteries 2*12V/ 2.3Ah sealed lead acid gel, self-regulated
    Battery replace Resistance 1.6Ω±10% if needed
    Battery low-voltage protection 21V
    The maximum and minimum electrical ratings for each input and output Detectots / zone lines: 15.2V-28V     Sounder lines:19-28V
    Fire protection/Fire routing lines:19-28V  Fault routing lines:18-28V
    Detectors wiring allowed each zone 16 points
    Max points (detector and MCP) per CIE 32 points
    Zone alarm current 6mA minimum/ 27mA maximum
    Sounder output 200mA maximum
    Fire routing/ Fault routing 200mA maximum each terminal
    Communication protocol 2 wires RS485 bus system
    EOL resistor for zone, inputs(Except for main power) and outputs 6.8K 1W
    Wires for 220V AC IN (recommended) 16AWG
    Wires connect power board to interface board (recommended) 20AWG
    Wire for main board wiring with interface board (recommended) 28AWG
    Fuse on power board 3A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow
    Fuses on interface board(general outputs) 0.2A /250V Glass tube fuse 5*20(mm) Fast/quick blow [*5pcs]
    Fuse on interface board(Main Power) 2A/ 250V Ceramic tube fuse 5*20(mm) Slowly blow
    Fuse on interface board(EM valve) 1.5A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow
    Environmental Class A temperature range: -5 to 40°C (23~104°F)
    Humidity: 5 to 95% RH, non-condensing
    Terminal blocks rating All terminals rated for 12 to18 AWG
    (0.75 to 2.5 mm2)
    Wires between interface board (Panel)and Detector  (recommended) 2-core shielded cable for 12 to18 AWG
    (0.75 to 2.5 mm2)
  • Fire detection tube type automatic fire detection and extinguishing device

    The fire detection tube automatic fire extinguishing device is a simple, low cost and highly reliable independent automatic fire extinguishing system. It does not depend on any power source and can op…

    • Advantages of automatic fire detection system

      The fire detection automatic fire extinguishing device can immediately and effectively extinguish the fire source, and has the following advantages:

      ● Unique fire extinguishing effect can effectively extinguish the fire in the bud.
      ● In case of fire, no power supply or manual operation is required, and the device will start automatically.
      ● The most suitable for unattended equipment and places that need protection.
      ● The detection reaction time is fast, reducing the loss caused by the spread of fire.
      ● The fire detection tube is not affected by any position, and can be extended to various complex flammable spaces or equipment.
      ● The fire detection tube is equivalent to a linear detector, which can detect fire and release fire extinguishing agent.
      ● A small amount of fire extinguishing agent can reduce pollution and damage to the surrounding environment.

      ● Greatly reduce the cost of each fire extinguishing.

      ● Easy to install and takes up very little space. The simple design minimizes installation and maintenance costs.
      ● If it is not completely submerged, it will not hurt people in the protection zone when released.
      ● No false alarms or false releases due to oil, dust, etc.
      ● The device has no electrical components, is not affected by vibration or shock, and does not affect operating functions.
      ● Because the fire detection tube is a flexible tube, it can be arbitrarily placed in various cable laying positions. This function makes up for the gap that cannot be extinguished by existing fire protection products.
  • Foam Fire Extinguishing Equipment

    The foam bladder tank is the main unit of the foam extinguishing system.

    The device consists of pressure tank, bladder, proportioner , pressure gauge, valves and pipeline. A pump is needed to supply pressurized water. When pressurized water flow through proportioner, a small part of water(3%-6&) flow into tank from branch pipe to press the bladder to swap out equal foam concentrate and then mix with another part of water(97%-93%) to foam foam solution in proportioner and provide to foam generator.


    • Horizontal Bladder tank


      Vertical bladder tank

  • Hanging type of fm200 automatic fire suppression system

    Hanging type of fm200 automatic fire suppression system
    Hanging type of fm200 automatic fire suppression system is mainly composed by two parts.
  • Maintance Switch AW-MS2158

    AW-MS2158 Maintance Switch is a necessary part of automatic gas extinguishing control system (AW-GEC2159).
    • Features: 
      1. Two “LEDS” indicate “SYSTEM ARMED” and “SYSTEM INACTIVE”.
      2. When the key is inserted and turned towards “SYSTEM INACTIVE”, the red LED illuminates and the green LED indicating “SYSTEM ARMED” turns off.
      3. The key can only be removed in the “SYSTEM ARMED” position.
      4. This panel is also available with the key removable in both the “ARMED” and the “INACTIVE” positions.
      5. The information is silk-screened on a two-gang stainless plate.
    • Parameters: 
      1. Switch rated at  5A 250VAC;
      2. The DC rating is 5A up to 30VDC;
      3. LEDS rated at 10mA each for a total current draw of 20mA.

      Wiring diagram: 

  • Manual Release Station AW-MRS2158

    AW-MRS2158 Manual Release Station is a necessary part of automatic gas extinguishing control system (AW-GEC2159).
    • Features: 
      1.Function: report of fire signals;
      2.Start method: manual press;
      3.The Manual release is connected with Fire fighting panel;
      4.There are three buttons on the station, one is START button, and another one is STOP button. When the START button is pressed, you can press RESTORE button to restore the start button.

    Parameters: 
    Operating voltage: DC24V

    Front description:

    Back terminal wiring: 

  • Mode Switch AW-GD203

    The AW-GD203 mode selection module is designed for the AW-GEC2169 gas fire extinguishing system. Used to remotely switch the manual /automatic valve activate mode.
    Model No: AW-DGD203
    Input voltage: 18VDC~28VDC
    Work current: ≤25mA
    Working environment: -10℃~50℃
    Protection level: IP30
    Product size: 110mm(L)*87mm(W)*39mm(H)
  • Network FM200(HFC-227ea) Fire Extinguishing System

    FM200 (Heptafluoropropane, HFC-227ea) automatic fire extinguishing system is a gas fire, automatic control and fire detection is one of the modern intelligent automatic fire extinguishing system.

    • Features: 
      1. The fire extinguishing speed, high efficiency, strong initiative.
      FM200 clean gas automatic fire extinguishing system can completely extinguish fire in 10 seconds, usually clean gas fire extinguishing agent FM – 200 relative to the reserve design fire extinguishing concentration is low, only 9%, FM – 200 clean fire extinguishing agent is liquid is stored and can be quickly purification clean fire extinguishing gas, highly motivated to put out a fire.
      1. ​Clean
      FM200 clean gas automatic fire extinguishing system is very suitable for protection of electrical, magnetic media, documents, or high value of collection and equipment, and the protected objects without damage, without leaving any residue after fire, do not interrupt the daily work of protected areas.
      1. The security
      FM200 clean fire extinguishing gas is internationally recognized as harmless to the human body of fire extinguishing agent, non-toxic and will not cause respiratory problems.FM – 200 clean gas automatic fire extinguishing system to release pressure of small, non-toxic, very suitable for resident staff reserves.
      1. Environmental
      FM200 clean fire extinguishing gas is not international environmental groups included in the stop the use of gas, will not damage the atmospheric ozone layer, the remaining period in atmosphere is only 31 ~ 42 years.
      1. Economic
      FM200 clean gas automatic fire extinguishing system for the current environmental protection laws and regulations, so without replacement and duplication of investment in the future.Can also be used in design of the combined distribution method design centralized storage systems, more economic efficient fire protection.FM – 200 clean gas automatic fire extinguishing system is small in size, number of cylinders is little, so can save the area between the gas cylinder or don’t need a cylinder.
      1. Mature
      FM200 clean gas is to use made in the United States dupont chemical company of technology of synthesis, around the world has tens of thousands of cases of successful application, have been excessive ten years of practice test.On the international supporting design and engineering specifications.

     

    • Parameters: 
      Filling pressure 4.2 MPa Extinguishing agent release time ≤10s
      Extinguishing agent filling density ≤950kg/m3 valve drive air pressure 6.0±1.0 MPa(20℃)
      System Power Supply AC220V/DC24V/1A System working environment temperature -10℃~55℃
      System protection limits area The largest single area 800m²;
      volume : the largest single area 3600m ³
      System start-up mode Automatic system startup,
      electrical manual,
      mechanical emergency manual.
      Storage bottle volume 70L,90L,120L,150L,180L

      Drawing:

      Fire suppression system FM200 drawing

  • Sequence Starter AW-GD205

    The Sequence Starter is designed to divide the valve signal output by the panel into four to delay the trigger one by one.

    • Surface mounting
    • LED indicator
    • MCU intelligent control
    • Automatic fault detection
    • Connection via high-quality terminal blocks
    • 6 Compatible with the latest standards
    • Operating voltage: 24VDC
    • Operating current: ≤25mA
    • Operating temperature: -10℃~55℃,Relative humidity: ≤95%(non-condensing) 3.4 Protection class: IP20
    • Application: For indoor use only
    • EM valve output current: 2A max
    • Materials and colors: SPCC, Red